Motor controller GCU
  • Motor controller GCU
0

Motor controller GCU

Model

KTZ35X28SJ30JLKJ

KTZ35X42SJ30JLKJ

KTZ54X18SJ30JLKJ

KTZ54X26SJ30JLKJ

Low voltage operating range(V)

9-32

9-32

9-32

9-32

Rated input voltage(V)

346

346

540

540

Input voltage range(V)

250-450

250-450

400-750

400-750

Rated current(A)/Time(min)

220/30min

220/30min

110/30min

130/30min

Rated power(kW)

60

60

50

60

Peak current(A)/TIMES(s)

280/30s

420/30s

180/30s

260/30s

Peak power(kW)

90

120

80

120

Bus capacitance capacity(uF)

300

400

150

150

 YElectric capacity(nF)

220

220

220

220

  Cooling method

Liquid cooling

Liquid cooling

Liquid cooling

Liquid cooling

Active discharge time of supporting capacitance(s)

≤3

≤3

≤3

≤3

Support the passive discharge time of the capacito(min)

≤3

≤3

≤3

≤3

It can be customized and developed according to customer requirements, such as power level, type of power device (half-bridge, full bridge, single tube, sic), application model and other multi-dimensional requirements, suitable for extended range and main drive application scenarios, soft decoding technology, based on simulink model development, integrated application development environment. Meet the ISO26262 functional safety specification

Model

KTZ35X28SJ30JLKJ

KTZ35X42SJ30JLKJ

KTZ54X18SJ30JLKJ

KTZ54X26SJ30JLKJ

Low voltage operating range(V)

9-32

9-32

9-32

9-32

Rated input voltage(V)

346

346

540

540

Input voltage range(V)

250-450

250-450

400-750

400-750

Rated current(A)/Time(min)

220/30min

220/30min

110/30min

130/30min

Rated power(kW)

60

60

50

60

Peak current(A)/TIMES(s)

280/30s

420/30s

180/30s

260/30s

Peak power(kW)

90

120

80

120

Bus capacitance capacity(uF)

300

400

150

150

 YElectric capacity(nF)

220

220

220

220

  Cooling method

Liquid cooling

Liquid cooling

Liquid cooling

Liquid cooling

Active discharge time of supporting capacitance(s)

≤3

≤3

≤3

≤3

Support the passive discharge time of the capacito(min)

≤3

≤3

≤3

≤3

It can be customized and developed according to customer requirements, such as power level, type of power device (half-bridge, full bridge, single tube, sic), application model and other multi-dimensional requirements, suitable for extended range and main drive application scenarios, soft decoding technology, based on simulink model development, integrated application development environment. Meet the ISO26262 functional safety specification